Jed Mecate personal email
- Valid
Jed Mecate phone numbers
Supervisor, assigned test/installation activities are carried out in accordance with applicable Project Specifications, Test Plans and Quality Assurance plans. Rollout Installations Supervision and Support for the ASP testers/installers.Troubleshooting / alarm clearance pertaining to KPI Performance issues, like : HOSR, CSSR, CDR and unavailability problem of the Network.
-
Field TechnicianT-Mobile Apr 2021 - PresentPennsylvania, United StatesFIELD OPERATIONS ENGINEERING DEPARTMENT -
System IntegratorGlotel Inc Nov 2013 - Present
-
Rbs 6000 IntegratorPt. Ericsson Indonesia/ Elabram Systems Jun 2011 - PresentJakarta Indonesia Give support to the Customer in case of Equipment failures, alarms and SW/HW faults in RNC & RBS. Perform remote troubleshooting at RNC related to Node B failures & monitor Network and Threshold Alarms. Perform troubleshooting of Imalink connections for particular sites with mismatch configuration of Physical links from Node B to RXI using moshell commands. Recreate ATM cross connections from Imagroup to VC’s in case of link congestions for the particular sites in RXI &… Show more Give support to the Customer in case of Equipment failures, alarms and SW/HW faults in RNC & RBS. Perform remote troubleshooting at RNC related to Node B failures & monitor Network and Threshold Alarms. Perform troubleshooting of Imalink connections for particular sites with mismatch configuration of Physical links from Node B to RXI using moshell commands. Recreate ATM cross connections from Imagroup to VC’s in case of link congestions for the particular sites in RXI & RBS. Perform actual Overview and troubleshooting of the Nodes on the operator’s Engineer/Technician OJT. Perform troubleshooting of alarms during malfunction of equipment boards such as CBU, TX6HS, RAX, RU, FU, RRU,ETFMX-11 and any other alarm that occur from the Radio Base Station Analyzing the problem that occurred in Node B especially for the Corrupted CV’s and script mismatch from RBS to RNC. Network monitoring via OSS CITRIX System for performances of RBS carrier status and alarms. Show less -
Trm/Rbs 2G & 3G EngineerEricsson Indonesia 2008 - Present -
Fe / System IntegratorAtlas Wireless Telecommunications Inc Dec 2014 - Sep 2023PennsylvaniaFE / System Integrator : AWAT Inc.December 2014 up to presentOperator/Vendor : T-Mobile / Ericsson projectLocation : PENSSYLVANIA • Perform LTE 2C Power upgrade & Integration of Ericsson Equipment.• Rip & replaced GSM outdoor cabinet to new RBS 6000 with 2G,3G & LTE• Alarms Troubleshooting for power cycling issue• Analyzing the problem that occurred in Node B especially for the corrupted CV’s and script mismatch from RBS to RNC• Power cabling, PDU PSU power… Show more FE / System Integrator : AWAT Inc.December 2014 up to presentOperator/Vendor : T-Mobile / Ericsson projectLocation : PENSSYLVANIA • Perform LTE 2C Power upgrade & Integration of Ericsson Equipment.• Rip & replaced GSM outdoor cabinet to new RBS 6000 with 2G,3G & LTE• Alarms Troubleshooting for power cycling issue• Analyzing the problem that occurred in Node B especially for the corrupted CV’s and script mismatch from RBS to RNC• Power cabling, PDU PSU power upgrade/DUL20 & DUS 31 migration to DUS 41. Integration of L700 Show less
-
Site EngineerEricsson Telecommunication Pte.Ltd Jul 2012 - Jun 2013Singapore And Brunei BranchPerform Node B to RNC onsite integration using moshell & RBS element manager.Supervise and provides technical support to our subcontractor during implementation activity in order to make it according to Ericsson standard
-
Rnc/Node B Support EngineerEgs- Ericsson Gestão E Serviços. May 2008 - Nov 2008Brazil FlorianopolisConfiguration & testing of Node B loading CVs and script files using Element Manager winfiol/ Moshell/Cygwin Performed clearing of all alarms @ RNC/RXI/ using winfiol/Moshell Cygwin Unix OperationsPerformed Upgrade of Node-B software from P5-P6-P7 versionTroubleshooting and O & M of RBS 3G (3206, 3018, 3418, 3107, 3518) Responsible for IMA configuration & creating ATM cross connects in Node BDesigning & loading the script(Basic, Initial, O & M, Site & cabinet equipment… Show more Configuration & testing of Node B loading CVs and script files using Element Manager winfiol/ Moshell/Cygwin Performed clearing of all alarms @ RNC/RXI/ using winfiol/Moshell Cygwin Unix OperationsPerformed Upgrade of Node-B software from P5-P6-P7 versionTroubleshooting and O & M of RBS 3G (3206, 3018, 3418, 3107, 3518) Responsible for IMA configuration & creating ATM cross connects in Node BDesigning & loading the script(Basic, Initial, O & M, Site & cabinet equipment CV)Closely coordinate with RNC to troubleshoot and loading carriers to make the site on air. Responsible for modifying the Node B script if required. Established test calls (voice and video), sms test, mms test, and HSDPA test (data upload and download) for each sector. Ensure the site will be properly functioning before declaring it to be on air.Responsible for all microwave radio system in case of equipment failurePerformed end to end test of E1 connection.Give support to the Customer in case of Equipment failures, alarms and SW/HW faults in RNC & RBS. Show less
-
Ran/Trm EngineerEricsson Pakistan (Covenant Ultratech Philippines ) Jan 2008 - Mar 2008 Testing & commissioning of RBS 2116, 2216 & 2308 Testing and configuration of Minilink Classic, TN (2P, 6P & 20P) Troubleshooting of all types of Minilink nodes using LCT MSM & Minilink Craft 1.1 Involved in the acceptance of Minilink nodes (Classic, TN ) and RBS Involve in upgrading the latest & safer R8A17 software versions for TN. Responsible for Clean up and rectification preparation for acceptance Closely coordinate with NOC to troubleshoot and loading… Show more Testing & commissioning of RBS 2116, 2216 & 2308 Testing and configuration of Minilink Classic, TN (2P, 6P & 20P) Troubleshooting of all types of Minilink nodes using LCT MSM & Minilink Craft 1.1 Involved in the acceptance of Minilink nodes (Classic, TN ) and RBS Involve in upgrading the latest & safer R8A17 software versions for TN. Responsible for Clean up and rectification preparation for acceptance Closely coordinate with NOC to troubleshoot and loading carriers to make the site on air. Established test calls (voice ), sms test. Supervised subcontractors for the Installation, in order to make it according to Ericsson Standards. Indoor coverage for customer according to its requirements. Performed and troubleshoots RBS equipment such as transceiver units (DRU), FU units, DXU units etc. Show less
-
Gsm/Minilink Tn Team LeaderEricsson Png (Dmn Global Network Support Services) Aug 2007 - Dec 2007 Testing & commissioning of RBS 2116, 2216 & 2308 Testing and configuration of Minilink Classic, TN (6P, 20P) Troubleshooting of all types of Minilink nodes using LCT & MSM Involved in the acceptance of Minilink nodes (Classic, TN ) and RBS Involve in upgrading the latest R8A17 software versions for TN. Upgrading traffic capacity of Minilink TN Responsible for Clean up and rectification preparation for acceptance Closely coordinate with NOC to troubleshoot… Show more Testing & commissioning of RBS 2116, 2216 & 2308 Testing and configuration of Minilink Classic, TN (6P, 20P) Troubleshooting of all types of Minilink nodes using LCT & MSM Involved in the acceptance of Minilink nodes (Classic, TN ) and RBS Involve in upgrading the latest R8A17 software versions for TN. Upgrading traffic capacity of Minilink TN Responsible for Clean up and rectification preparation for acceptance Closely coordinate with NOC to troubleshoot and loading carriers to make the site on air. Show less
-
Node-B/Gsm/Trm EngineerEricsson Indonesia (Elabram Systems) Dec 2006 - Mar 2007 Configuration & testing of Node B while loading CVs and script files Testing and configuration of Minilink Classic, TN (2P, 6P, 20P) & Hicap Troubleshooting and O & M of all types of Minilink nodes using LCT & MSM Involved in the acceptance of Minilink nodes (Classic, TN & Hicap) Troubleshooting and O & M of RBS 3G (3206, 3106, 3412, 3107, 3101, & 3303) Involve in upgrading the latest 3G RBS R_30H software versions. Responsible for IMA configuration & creating… Show more Configuration & testing of Node B while loading CVs and script files Testing and configuration of Minilink Classic, TN (2P, 6P, 20P) & Hicap Troubleshooting and O & M of all types of Minilink nodes using LCT & MSM Involved in the acceptance of Minilink nodes (Classic, TN & Hicap) Troubleshooting and O & M of RBS 3G (3206, 3106, 3412, 3107, 3101, & 3303) Involve in upgrading the latest 3G RBS R_30H software versions. Responsible for IMA configuration & creating ATM cross connects in Node B Designing & loading the script(Basic, Initial, O & M, Site & cabinet equipment CV) Show less
-
Rbs 3G IntegratorEricsson Perth W.A (Electel Ab) Mar 2006 - Sep 2006 Responsible for technical support to the subcontractors in order to meet the Ericsson standards. Supervision of Installation & commissioning of Ericsson Node B (3206, 3107 & 3303) in order to make it according to Ericsson Standards Configuration & testing of Node B while loading CVs and script files Troubleshooting and O & M of RBS 3G (3206, 3107, Involve in upgrading the latest 3G RBS software versions. Responsible for IMA configuration & creating ATM cross… Show more Responsible for technical support to the subcontractors in order to meet the Ericsson standards. Supervision of Installation & commissioning of Ericsson Node B (3206, 3107 & 3303) in order to make it according to Ericsson Standards Configuration & testing of Node B while loading CVs and script files Troubleshooting and O & M of RBS 3G (3206, 3107, Involve in upgrading the latest 3G RBS software versions. Responsible for IMA configuration & creating ATM cross connects in Node B Involve in script loading(Basic CV, Initial CV, O & M CV, Site & cabinet equipment CV) Closely coordinate with RNC to troubleshoot and loading carriers to make the site on air. Show less
Jed Mecate Skills
Jed Mecate Education Details
-
Electronics & Communication
Frequently Asked Questions about Jed Mecate
What company does Jed Mecate work for?
Jed Mecate works for T-Mobile
What is Jed Mecate's role at the current company?
Jed Mecate's current role is T-Mobile.
What is Jed Mecate's email address?
Jed Mecate's email address is jm****@****hoo.com
What is Jed Mecate's direct phone number?
Jed Mecate's direct phone number is +161032*****
What schools did Jed Mecate attend?
Jed Mecate attended Mindanao State University.
What are some of Jed Mecate's interests?
Jed Mecate has interest in International Travel, Basketball, Strategic Planning, Singing, Organizational Development, Mix Martial Arts.
What skills is Jed Mecate known for?
Jed Mecate has skills like 2g, 3g, Gsm, Rnc, Microwave, Wcdma, Ran, Telecommunications, Transmission, Rollout, Software Installation, Bss.
Who are Jed Mecate's colleagues?
Jed Mecate's colleagues are Delano Owens, Marcus Martin, Alberto Miles, Joseph Dimian, Jacob Reasoner, Jay Osborn, Han Xiao.
Free Chrome Extension
Find emails, phones & company data instantly
Aero Online
Your AI prospecting assistant
Select data to include:
0 records × $0.02 per record
Download 750 million emails and 100 million phone numbers
Access emails and phone numbers of over 750 million business users. Instantly download verified profiles using 20+ filters, including location, job title, company, function, and industry.
Start your free trial