Ran/Tran Coordinator At Ericson Vietnam
Eicsson Viet Nam
Suppervisor
- Supervise testing and commissing RBS 2216, RBS 2111 and TN’s (2P,6P, 20P using Minilink Craft 2.0), Delta power supply cabinet.- Conducts feeder cable Sweeptest ( DTF, VSWR/Freq).- TN 2p, 6p,20p traffic routing provisoning in TN backbone MMU, NPU.- Link Allignment (1+0, 1+1 configuration ) RAU use RAU2N 7 & 13GHZ ; C-QPSK-16 QM- In-charge in building/ Start-up of DCN network for NMS, employing multil-OSPF, ABR( Area Border Router TN), ASBR( Autonomous System Border Router TN ), PPPs( point- to- poin link in TN) , Configuration of static route /Default Getways of TN, NE-Ethenet IPs of TN, cross connection according to transmission planing/ MUX PLAN, and test BER.- Recomment / formulate solution on intergration and commising roadblocks encountered in the file.- Support another team during fault isolation and clearing.- Initiates transfer of knowledge/ tranning on local engineers- Intergarte RBS to BSC , Teas, Commision, Fault isolation and clearing RBS 2216 and RBS 2111- RBS software upgarde / RBS reconfiguration ( using OMT R35_7) - Initiates TN software upgrade module and baseline.- Initiates test calls and basic intergration test cases and fill out test sheets.- Initiate A-Bis traffic routing/ provisioning/ SW and physical cross connection on TN network ( MMU 2P/ 2E 155, LTU’s e/o) to fiber or DDF’s.- Conducts Site Acceptances interfacing with Ericsson and Ericsson Subcontract for Acceptance- Inspect installation follow Red Lines in SIDs