Mechanical Engineering Intern
Delavan, Wisconsin, United States
•Achieved 85% reduction in priming times at 25’ depths by optimizing self-priming booster pump with integration of cobalt priming stage•Reduced flange torque 56.8% by redesigning jet pump sealing mechanism through iterative O-ring and groove refinements, and reliability tests•Conducted Net Positive Suction Head (NPSH) tests, performance tests, and priming tests to evaluate effectiveness of new priming stage•Engaged in leadership development with mentorship, senior leader sessions, and cohort activities to enhance skills and industry knowledge